239 research outputs found

    An Efficient and Secure m

    Get PDF
    Recent rapid developments in wireless and mobile IT technologies have led to their application in many real-life areas, such as disasters, home networks, mobile social networks, medical services, industry, schools, and the military. Business/work environments have become wire/wireless, integrated with wireless networks. Although the increase in the use of mobile devices that can use wireless networks increases work efficiency and provides greater convenience, wireless access to networks represents a security threat. Currently, wireless intrusion prevention systems (IPSs) are used to prevent wireless security threats. However, these are not an ideal security measure for businesses that utilize mobile devices because they do not take account of temporal-spatial and role information factors. Therefore, in this paper, an efficient and secure mobile-IPS (m-IPS) is proposed for businesses utilizing mobile devices in mobile environments for human-centric computing. The m-IPS system incorporates temporal-spatial awareness in human-centric computing with various mobile devices and checks users’ temporal spatial information, profiles, and role information to provide precise access control. And it also can extend application of m-IPS to the Internet of things (IoT), which is one of the important advanced technologies for supporting human-centric computing environment completely, for real ubiquitous field with mobile devices

    CHANGES IN MUSCLE ACTIVITY PATTERN IN LOWER LIMB EXTREMITY DURING PEDALLING BY SADDLE HEIGHT

    Get PDF
    As a preliminary study for a preferential saddle height for cyclist, muscle activity pattern in lower limb extremity between preferred and higher saddle height during pedalling was compared. Seven cyclists performed 3 min sub-maximal pedalling under two different saddle heights. Range of motion (ROM) of muscle length, onset-timing of muscle activity, and amount of muscle activity in biceps femoris (BF), vastus lateralis (VL), gastrocnemius (GM), and tibialis anterior muscles (TA) were used to compare changes in muscle activity pattern due to saddle height. Results showed that there was a significant difference in ROM of VL and that of TA (

    Characteristics of Ni-Doped IZO Layers Grown on IZO Anode for Enhancing Hole Injection in OLEDs

    Get PDF
    The preparation and characteristics of a Ni-doped indium zinc oxide (NIZO) layer were investigated to enhance hole injection in organic light emitting diodes (OLEDs). A thin NIZO layer with a thickness of 5 nm was cosputtered onto an indium zinc oxide (IZO) anode using tilted Ni and IZO dual targets dc magnetron sputtering at room temperature in a pure Ar atmosphere. Using 3 W of Ni dc power, we can obtain a NIZO (5 nm)/IZO (135 nm) double-layer anode with a sheet resistance of 30.04 / and an optical transmittance of 83.8% at a wavelength of 550 nm. In addition, it was found that the work function of the NIZO layer was higher than that of a pure IZO anode due to the presence of a NiOx phase in the NIZO layer. An increase of Ni dc power above 7 W significantly degrades the electrical and optical properties in the NIZO layer. X-ray diffraction examination demonstrated that the NIZO layer consisted of an amorphous structure regardless of the Ni dc deposition power due to low substrate temperature. Furthermore, an OLED fabricated on the NIZO layer exhibited a higher current density, luminance, and efficiency due to improved hole injection by the high work function NIZO. These results indicate that the NIZO/IZO anode scheme is a promising anode material system for enhancing hole injection from the anode into the active layer of OLEDs.The authors acknowledge financial support from LG Displays, OLED Panel Development team

    Kikuchi-Fujimoto disease mimicking malignant lymphoma with 2-[F]fluoro-2-deoxy-D-glucose PET/CT in children

    Get PDF
    PurposeKikuchi-Fujimoto disease (KFD) is a benign disease, which is characterized by a cervical lymphadenopathy with fever, and it often mimics malignant lymphoma (ML). 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (18F-FDG PET/CT) is a powerful imaging modality for the diagnosis, staging and monitoring of ML, with the limitations including the nonspecific FDG uptake in infectious or inflammatory processes. This study compared clinical manifestations and PET/CT findings between KFD and ML patients.MethodsWe retrospectively reviewed the medical records of 23 patients with KFD and 33 patients with ML, diagnosed histopathologically, between January 2000 and May 2013 at the Department of Pediatrics, Yeungnam University Medical Center. Among them, we analyzed the clinical manifestations, laboratory findings and characteristics, and the amount of 18F-FDG uptake between 8 KFD and 9 ML patients who had 18F-FDG PET/CT.ResultsThe 18F-FDG PET/CT maximum standardized uptake values (SUVmax) ranged from 8.3 to 22.5 (mean, 12.0) in KFDs, and from 5.8 to 34.3 (mean, 15.9) in MLs. There were no significant differences in SUVmax between KFDs and MLs. 18F-FDG PET/CT with ML patients showed hot uptakes in the extranodal organs, such as bone marrow, small bowel, thymus, kidney, orbit and pleura. However, none of the KFD cases showed extranodal uptake (P<0.001). 18F-FDG PET/CT findings of KFD with nodal involvement only were indistinguishable from those of ML.ConclusionPatients who had extranodal involvement on PET/CT were more likely to have malignancy than KFD

    Development of tricuspid regurgitation late after left-sided valve surgery: a single-center experience with long-term echocardiographic examinations

    Get PDF
    OBJECTIVES: This study sought to investigate the incidence and identify the predictors of significant tricuspid regurgitation (TR) development long after left-sided valve surgery. METHODS: Of 615 patients who underwent surgery for left-sided valve disease between 1992 and 1995, 335 patients without significant TR who completed at least 5 years of clinical and echocardiographic follow-up were enrolled. Late significant TR development was assessed by echocardiography with a mean follow-up duration of 11.6 +/- 2.1 years. RESULTS: Significant late TR was found in 90 patients (26.9%). Patients with late TR showed an advanced age (47.6 +/- 13.4 vs 44.3 +/- 13.2 years, P = .04), a higher prevalence of preoperative atrial fibrillation (83.3 vs 46.5%, P < .001), a greater left atrial dimension (56.9 +/- 13.2 vs 52.4 +/- 11.5 mm, P = .006), and a higher prevalence of prior valve surgery (40.0 vs 25.3%, P = .01). In addition, late TR occurred more frequently in patients who had undergone mitral valve surgery than in those who did not (93.3 vs 72.2%, P < .001). However, multivariate analysis showed that the presence of preoperative atrial fibrillation (odds ratio 5.37; 95% CI 2.71-10.65; P < .001) was the only independent factor of late TR development. Patients who developed late TR had a lower event-free survival rate than those who did not (P = .03). CONCLUSIONS: The development of significant TR long after left-sided valve surgery is not uncommon with an estimated incidence of 27% and is closely associated with a poor prognosis. The presence of preoperative atrial fibrillation was identified as the only independent predictor of the development of late TR

    Augmented Mechanical Forces of the Surface-Modified Nanoporous Acupuncture Needles Elicit Enhanced Analgesic Effects

    Get PDF
    Over the past several decades, clinical studies have shown significant analgesic effects of acupuncture. The efficacy of acupuncture treatment has improved with the recent development of nanoporous needles (PN), which are produced by modifying the needle surface using nanotechnology. Herein, we showed that PN at acupoint ST36 produces prolonged analgesic effects in an inflammatory pain model; the analgesic effects of PN acupuncture were sustained over 2 h, while those using a conventional needle (CN) lasted only 30 min. In addition, the PN showed greater therapeutic effects than CN after 10 acupuncture treatments once per day for 10 days. We explored how the porous surface of the PN contributes to changes in local tissue, which may in turn result in enhanced analgesic effects. We showed that the PN has greater rotational torque and pulling force than the CN, particularly at acupoints ST36 and LI11, situated on thick muscle layers. Additionally, in ex vivo experiments, the PN showed greater winding of subcutaneous connective tissues and muscle layers. Our results suggest that local mechanical forces are augmented by the PN and its nanoporous surface, contributing to the enhanced and prolonged analgesic effects of PN acupuncture.1
    corecore